Product Description
Features
- Simpler,Smarter and reliable gas detector with digital display .
- Simple and cost effective installation .
Rugged, compact and lightweight design. - Environment friendly product .
- NDIR (non dispersive infrared sensor) mounted type approvals
- Ex d llC T5 (KD-12A/B/C)
- Ex d llC T5 (KD-12D/R/O
- ATEX,Standard (KD-12A/ B/C /D/O/R)
- CE marking (EMC directive )
- SIL (KD12B)
Technical Specifications
| Model | KD-12A | KD-12B | KD-12C |
| Detection Principle | Hot wire semiconductor | Catalytic combustion | Thermal conductivity |
| Gas Detected | Combustible gas, Toxic gas | Hydrogen, Helium, Carbon dioxide |
| Sampling Method | Diffusion |
| Detection Range | As per specifications |
| Alarm Set Value | As per specifications |
| Alarm Accuracy | Combustible gas: 25% of alarm set value Toxic gas: 30% of alarm set value |
| Alarm Delay | Combustible gas: within 30s at 1.6 times of alarm set value Toxic gas: within 60s at 1.6 times of alarm set value |
| Alarms | Gas alarm: Red LED lamp flashes Trouble alarm: Yellow LED lamp flashes (sensor trouble, power voltagemalfunction, etc.) |
| Display | 4-digit digital LED display |
| Output | Gas concentration analog signal 4-20mADC (common to the negative side of power supply) Gas alarm contact (one stage only)*1 1a no-voltage contact output, Non-latching Rated load: 0.5A at 250VAC or 0.5A at 30VDC (resistance load) |
| Operation | At 4 points of magnetic switches |
| Approvals | Ex d IIC T5 (TIIS) II 2 G Ex db IIC T5 Gb (ATEX) Ex db IIC T5 Gb (IECEx) |
| Model | KD-12R | KD-12D | KD-12O |
| Detection Principle | NDIR (Non-dispersive infrared) | Electro chemical cell | Galvanic cell |
| Gas Detected | Methane, Carbon dixide | Carbon monoxide | Hydrogen sulfide | Oxygen |
| Sampling Method | Diffusion type |
| Detection Range | As per specifications | 0 to 100 ppm, 0 to 150 ppm, or 0 to 250 ppm*3 | 0 to 30 ppm or 0 to 50 ppm*3 | 0 to 25.0 vol% |
| Alarm Set Value | As per specifications | FS100ppm: 25ppm (recommendation) FS150/250ppm: 50ppm (recommendation) | 10ppm | 18.0vol% |
| Alarm Accuracy | 25% of alarm set value | 30% of alarm set value | 1.0vol% of alarm set value |
| Alarm Delay | Within 30s at 1.6 times of alarm set value | Within 60 s at 1.6 times of alarm set value | Within 5s to reach 18vol% under conditionof 10vol%*4 |
| Alarms | Gas alarm: Red LED lamp flashes Trouble alarm: Yellow LED lamp flashes (sensor trouble, power voltage malfunction,etc.) |
| Display | 4-digit digital LED display |
| Output | Gas concentration analog signal 4-20mADC (common to the negative side of power supply) Gas alarm contact (one stage only)*1 1a no-voltage contact output, Non-latching Rated load: 0.5A at 250VAC or 0.5A at 30VDC (resistance load) |
| Operation | At 4 points of magnetic switches |
| Approvals | Ex d IIB T5 (TIIS) II 2 G Ex db IIC T5 Gb (ATEX) Ex db IIC T5 Gb (IECEx) |
| Degree of Protection | IP65 |
| CE marked | Complied with CE Directive 2004/108/EC |
| Applicable Cable | Cable out diameter: 10-13mm 5-conductor cable*1: CVV-S 1.25mm23-conductor cable: CVV-S 2mm2 or 1.25mm2 |
| Operating Temperature/Humidity*2 | -10 to +50 C 10 to 90 %RH (0 to 50 C) | -10 to +40 C 30 to 85 %RH | 0 to +40 C 30 to 85 %RH |
| Power Supply | 24VDC (20%) |
| Power Consumption | 2.2W max. | 1.2W max. |
| Dimensions | W158 x H120 x D68 mm (excluding protrusion) |
| Weight | Approx. 1.3kg |
Reliable Real-Time Gas Concentration MonitoringThis gas detectors LED digital display ensures precise, immediate visibility of gas concentration levels. Its high sensitivity and rapid response time (30 seconds) make it ideal for critical industrial safety applications. The combination of diffusion sampling and advanced sensing technology allows for effective monitoring across diverse environments.
Robust and Adaptable Industrial DesignThe devices flameproof enclosure, durable ABS plastic/metal construction, and IP65 rating guarantee resilience in challenging settings. Installation is streamlined with a wall-mount bracket and a standard 1.5m cable (customizable). Versatile power, communication, and output options allow seamless integration into established safety systems in factories, laboratories, and workspaces.
FAQs of Diffusion Type With Led Concentration Display:
Q: How does the LED concentration display enhance workplace safety?
A: The LED digital display provides operators with immediate, real-time gas concentration readings, allowing for quick identification and response to potentially hazardous gas levels. It enables proactive safety management in critical environments such as factories and laboratories.
Q: What calibration methods are available for this gas detector?
A: This device supports both manual and automatic calibration, offering flexibility to meet different operational requirements. Regular calibration ensures long-term accuracy and reliability, crucial in industrial gas monitoring applications.
Q: Where can this gas detector be installed and what are its mounting options?
A: The detector is suitable for various industrial environments, including factories, laboratories, and workspaces. It comes with a mounting bracket for secure wall installation, and the standard 1.5m cable can be customized to fit specific site requirements.
Q: What types of alarms and alerts does the device provide in case of gas detection?
A: Upon detecting abnormal gas levels, the device activates both a buzzer for audible warning and visual alerts via the LED display, ensuring that personnel are promptly notified to take necessary action.
Q: What are the main benefits of the overvoltage and reverse polarity protection features?
A: These protections safeguard the detectors circuitry from accidental wiring errors or voltage spikes, enhancing operational reliability and extending the units lifespan in demanding industrial environments.
Q: Can the device data be integrated with existing monitoring systems?
A: Yes, with support for RS485/Modbus communication protocols, analog and digital signal outputs, the detector allows seamless integration into industrial automation or safety monitoring systems. Optional wireless connectivity and data logging further enhance interoperability and reporting capabilities.