Product Description
We have uniquely positioned ourselves as one of the topmost enterprises engaged in manufacturing, exporting and supplying Portable Grease Steel Dust Meter. Offered meter is ideal for measuring the density of steel dust in grease. It is manufactured by our team of experts with the help of advanced methodology using quality tested components. Furthermore, our esteemed clients can get this Portable Grease Steel Dust Meter from us at competitive prices.
Manufactured using high quality materials and modern technology, this Portable Grease Steel Dust Meter is offered to clients in a wide range of specifications to meet their individual requirements. It enables diagnosis of the wear condition of bearings before an increase in vibration. This device is highly acclaimed by clients for its easy operation, accuracy and long working life. The dust meter is manufactured by our highly skilled team using best quality materials, procured from reputed vendor in market.
Features:
- Allows diagnosis of wear condition of grease dust
- Helps monitoring and simple diagnosis
- Excellent battery life
- Rugged design & accurate monitoring
Applications:
- Trend monitoring and simple diagnosis of the wear.
- Condition of greased gears, bearings, etc.
- Pre diagnosis for SOAP method and Ferrography method.
Technical Specifications
|
Model
|
SDM-72
|
|
Measurement principle
|
Magnetic balance type electromagnetic method
|
|
Substance measured
|
Steel dust concentration in grease
|
|
Measurement range
|
0-5.000%wt
|
|
Resolution
|
0.001%wt
|
|
Zero adjustment
|
Automatic adjustment
|
|
Amount of sample
|
Approx. 0.8ml
|
|
Power source
|
4x AA(R6) alkaline dry cells
|
|
Battery life
|
Up to 30 hours by alkaline cells
|
|
Operating temperature
|
0 to 40DegC
|
|
Dimensions
|
W 84 x H190 x D40mm
|
|
Weight
|
Approx. 500g(including batteries)
|
|
Standard Accessories
|
Carrying case, Grease sampling spatula, Grease sample case(10 pieces),4x AA(R6) alkaline dry cells.
|

Technical Details 
Reliable Measurement SolutionEngineered for versatility, the Portable Grease Steel Dust Meter guarantees accurate detection of steel dust and grease in a variety of industrial contexts. Its adaptable configuration allows users to select particulars such as port sizes, sensor types, and test ranges to best fit their application. The durable plastic construction ensures that the device withstands rigorous use while remaining lightweight and easy to transport between job sites.
Tailored for Industrial NeedsThis meter can be precisely configured to meet specific operational requirements, including number of specimens, operating methods, and test materials. The flexible design ensures optimal performance in diverse environments. Whether for ongoing maintenance, compliance assessments, or quality assurance in manufacturing, this device provides consistent, trustworthy results.
FAQs of Portable Grease Steel Dust Meter:
Q: How does the Portable Grease Steel Dust Meter work?
A: This electronic meter operates by utilizing a specialized sensor that detects and quantifies steel dust and grease on sampled materials. It translates these readings into easily interpretable digital values, facilitating quick assessment of contamination levels.
Q: What are the typical applications for this device in industrial settings?
A: The Portable Grease Steel Dust Meter is widely used for on-site testing in manufacturing plants, maintenance checks, routine inspections, and quality control processes where monitoring steel dust and grease contamination is critical to equipment longevity.
Q: When should you use this meter for optimal results?
A: Deploy the meter during routine maintenance schedules, before or after manufacturing cycles, or anytime contamination monitoring is required. Frequent use helps prevent equipment degradation and ensures compliance with industry standards.
Q: Where can this device be sourced in India?
A: The meter is available from trusted distributors, exporters, importers, manufacturers, service providers, suppliers, and traders throughout India, ensuring comprehensive coverage and support for industrial clients.
Q: What is the process for setting up and using the device?
A: Setup involves configuring the meters operational settings to match your applicationsuch as sensor type, desired test range, and port size. Once calibrated, simply collect a specimen and follow the user guide to run the measurement process via its designated operating mode.
Q: What benefits does this device offer over conventional methods?
A: Unlike manual testing, this portable meter delivers rapid, accurate results on-site, reducing risk of human error and minimizing downtime. Its flexibility ensures efficiency and improved asset management across different testing scenarios.
Q: How is the device maintained for consistent accuracy?
A: Routine cleaning, calibration, and following the recommended usage procedure are key for sustained performance. Periodic checks with certified reference samples are advised to ensure measurement precision is preserved over time.